BLITZ - Ball Valve
blitz-fire-hose-branch-pipe-shut-off-lever-main-ksa
blitz-fire-hose-branch-pipe-shut-off-lever-specs-ksa

Click on the image to enlarge it

BLITZ

Click here for more BLITZ
Shut-Off Lever — Interchangeable Nozzle

BLITZ Fire Hose Branch Pipe With Shut-Off Lever — Aluminium Alloy Body with 1.5" and 2.5" NST Inlets and an Interchangeable Nozzle

Overview

  • The BLITZ branch pipe is the component fitted at the end of a fire hose that turns the water flow into a directed jet. Before any other specification, a correct purchase begins with one question.
  • First and above all: does the coupling match your hose? This branch pipe comes with an NST threaded inlet in 1.5 inch or 2.5 inch, and NST is an American thread with a defined form and pitch that differs from the other couplings used across the region, such as British instantaneous couplings or BSP threads. A branch pipe that does not match the hose thread cannot be fitted and cannot be adapted on site — which makes checking the coupling type in your hose cabinets the first step, ahead of price and ahead of size. The product data also states that connections are available "or as required", meaning the branch pipe can be supplied with a coupling that matches your network if it is not NST — our sales team settles that when preparing the quotation.
  • Second: the shut-off lever and the ball valve. This is the most important functional feature of this model. A plain branch pipe without a valve means water is controlled from the distant hose cabinet valve; so if the operator needs to stop the water to advance, to reposition, or to avoid flooding what need not be flooded, he has to go back to the valve or shout to whoever is standing at it. Here the ball valve sits in the operator's hand, opened and closed with a single movement of a lever, and a ball valve specifically gives quarter-turn opening and closing with less resistance to flow in the fully open position than other valve types.
  • Third: the nozzle is interchangeable. The standard size is 20 mm, with 16, 19 and 22 mm options. Nozzle size is what sets the flow rate and the reach at a given pressure: a smaller nozzle gives greater reach at a lower flow, a larger one gives a higher flow at a shorter reach. Having four sizes within the same model means the network's performance can be tuned to the pump pressure actually available rather than replacing the whole branch pipe.
  • The body is aluminium alloy in a natural aluminium finish, and the branch pipe weighs approximately 2.5 to 3.0 kg — a tangible difference for anyone holding it for an extended period, on a ladder or on a raised platform. The red PVC grip gives a non-slip hold and marks the branch pipe out visually. The flow pattern is straight jet. Available through Al-Najma Al-Wataniyah with guaranteed quality and fast delivery across Riyadh, Dammam, and all KSA regions.

Technical Specifications

SpecificationValue
CategoryFire fighting equipment — fire hose branch pipe
BrandBLITZ
Product NameFire Hose Branch Pipe
TypeLever operated
ValveBall valve shut-off
Body MaterialAluminium alloy
HandleRed PVC grip
Inlet Connections1.5" NST · 2.5" NST · or as required
Nozzle Size20 mm standard — 16, 19 and 22 mm options
Flow TypeStraight jet
FinishNatural aluminium
Approx. Weight2.5 – 3.0 kg
SKUBLITZ-FHBP-LEVER

Size & Color Table

  • First — inlet connection sizes:
Inlet SizeThread TypeTypical Use
1.5 inchNSTHose reels and indoor fire hose cabinets in buildings
2.5 inchNSTIndustrial firefighting networks and higher-flow hydrant outlets
As requiredSpecified with the orderNetworks using a different coupling — review with the sales team
  • Second — available nozzle sizes:
Nozzle SizeStatusPractical Effect at Constant Pressure
16 mmOptionLower flow, greater reach
19 mmOptionA middle point between reach and flow
20 mmStandardThe size supplied by default
22 mmOptionHigher flow, shorter reach

Certificates & Standards

  • EN 671-1 and EN 671-2 (fixed hose reels and hose systems and the equipment fitted to them)
  • BS 336 (the British specification for fire hose couplings and equipment)
  • NFPA 1964 (the American specification for spray nozzles) — a knowledge reference
  • Saudi Civil Defence requirements for firefighting networks and hose cabinets

Industrial Applications

  • B2B Sectors — Detailed Engineering Use Case:
Sector / ApplicationEngineering Use Case Details
Fire brigades and Civil Defence stationsA ball valve in the operator's hand to control water without returning to the network valve
Industrial plants and factoriesA 2.5 inch inlet for higher-flow firefighting networks, with the nozzle chosen to suit the pump pressure
Warehouses and distribution centresA 1.5 inch inlet for hose reels and indoor fire hose cabinets
Oil and gas facilitiesAn aluminium body in a natural finish and a light weight for extended handling during operations
Commercial buildings and towersThe light weight matters when holding the branch pipe on stairs and raised platforms
Marine protection and portsA straight jet with long reach for the open distances found on quaysides

B2B Supply Info

FieldValue
Lead Time2-3 Business Days
CoverageRiyadh · Dammam · Jeddah · Jubail · Yanbu · All KSA
Project SupplyAvailable — contact sales team to survey the number of hose cabinets and their coupling type before the supply order is raised

Frequently Asked Questions

Q1: How do I make sure the branch pipe matches our hoses?

  • By checking the coupling type in your hose cabinets first. This branch pipe comes with an NST thread in 1.5 or 2.5 inch, an American thread with a defined form and pitch that does not match British instantaneous couplings or BSP threads. A mismatched branch pipe cannot be fitted and cannot be adapted on site. The product data states that connections are available "as required", so if your network uses a different coupling, contact our sales team before ordering.

Q2: What do the ball valve and shut-off lever give me?

  • They put control of the water in the operator's hand rather than at the distant hose cabinet valve. Water can be stopped instantly to advance, to reposition or to avoid flooding what need not be flooded, then reopened at once. A ball valve specifically gives quarter-turn opening and closing of the lever, with less resistance to flow in the fully open position than other valve types.

Q3: How do I choose the nozzle size?

  • Nozzle size sets the relationship between flow and reach at a given pressure: a smaller nozzle (16 mm) gives greater reach at a lower flow, a larger one (22 mm) gives a higher flow at a shorter reach, and 20 mm is the standard size supplied by default. The choice rests on the pump pressure and flow actually available on your network, and we recommend consulting the network engineer before fixing the size for bulk quantities.

Q4: What is the rated working pressure?

  • The manufacturer's data sheet gives two pressure figures — 7 to 16 bar and 21 bar — without identifying which is the working pressure and which is the test pressure. Because that figure feeds directly into the project specification and into pump selection, we request written confirmation from the manufacturer with every project order before relying on it. Contact our sales team for the confirmation applying to your order.

Q5: Is delivery available to Riyadh, Dammam, and all KSA regions?

  • Yes, supply is available across all KSA regions with bulk quantities available for equipping hose cabinets and firefighting networks, with the inlet size and nozzle size specified per site at order time.

Internal Links

_________________________________________________________________________________________

Copyright © 2026 - (Al-Najma Al-Wataniyah Est.) - All Rights Reserved - KSA

We are committed to providing the highest quality standards for our customers in the Kingdom of Saudi Arabia, supplying accreditation certificates or approved technical data sheets for every product so your project requirements are met.

Read more
SKU : BLITZ-FHBP-LEVER

143.75

VAT included
Weight 2 KG

Drag & drop file

Browse

Secure Shopping, Your Data is Always Protected

Overview

  • The BLITZ branch pipe is the component fitted at the end of a fire hose that turns the water flow into a directed jet. Before any other specification, a correct purchase begins with one question.
  • First and above all: does the coupling match your hose? This branch pipe comes with an NST threaded inlet in 1.5 inch or 2.5 inch, and NST is an American thread with a defined form and pitch that differs from the other couplings used across the region, such as British instantaneous couplings or BSP threads. A branch pipe that does not match the hose thread cannot be fitted and cannot be adapted on site — which makes checking the coupling type in your hose cabinets the first step, ahead of price and ahead of size. The product data also states that connections are available "or as required", meaning the branch pipe can be supplied with a coupling that matches your network if it is not NST — our sales team settles that when preparing the quotation.
  • Second: the shut-off lever and the ball valve. This is the most important functional feature of this model. A plain branch pipe without a valve means water is controlled from the distant hose cabinet valve; so if the operator needs to stop the water to advance, to reposition, or to avoid flooding what need not be flooded, he has to go back to the valve or shout to whoever is standing at it. Here the ball valve sits in the operator's hand, opened and closed with a single movement of a lever, and a ball valve specifically gives quarter-turn opening and closing with less resistance to flow in the fully open position than other valve types.
  • Third: the nozzle is interchangeable. The standard size is 20 mm, with 16, 19 and 22 mm options. Nozzle size is what sets the flow rate and the reach at a given pressure: a smaller nozzle gives greater reach at a lower flow, a larger one gives a higher flow at a shorter reach. Having four sizes within the same model means the network's performance can be tuned to the pump pressure actually available rather than replacing the whole branch pipe.
  • The body is aluminium alloy in a natural aluminium finish, and the branch pipe weighs approximately 2.5 to 3.0 kg — a tangible difference for anyone holding it for an extended period, on a ladder or on a raised platform. The red PVC grip gives a non-slip hold and marks the branch pipe out visually. The flow pattern is straight jet. Available through Al-Najma Al-Wataniyah with guaranteed quality and fast delivery across Riyadh, Dammam, and all KSA regions.

Technical Specifications

SpecificationValue
CategoryFire fighting equipment — fire hose branch pipe
BrandBLITZ
Product NameFire Hose Branch Pipe
TypeLever operated
ValveBall valve shut-off
Body MaterialAluminium alloy
HandleRed PVC grip
Inlet Connections1.5" NST · 2.5" NST · or as required
Nozzle Size20 mm standard — 16, 19 and 22 mm options
Flow TypeStraight jet
FinishNatural aluminium
Approx. Weight2.5 – 3.0 kg
SKUBLITZ-FHBP-LEVER

Size & Color Table

  • First — inlet connection sizes:
Inlet SizeThread TypeTypical Use
1.5 inchNSTHose reels and indoor fire hose cabinets in buildings
2.5 inchNSTIndustrial firefighting networks and higher-flow hydrant outlets
As requiredSpecified with the orderNetworks using a different coupling — review with the sales team
  • Second — available nozzle sizes:
Nozzle SizeStatusPractical Effect at Constant Pressure
16 mmOptionLower flow, greater reach
19 mmOptionA middle point between reach and flow
20 mmStandardThe size supplied by default
22 mmOptionHigher flow, shorter reach

Certificates & Standards

  • EN 671-1 and EN 671-2 (fixed hose reels and hose systems and the equipment fitted to them)
  • BS 336 (the British specification for fire hose couplings and equipment)
  • NFPA 1964 (the American specification for spray nozzles) — a knowledge reference
  • Saudi Civil Defence requirements for firefighting networks and hose cabinets

Industrial Applications

  • B2B Sectors — Detailed Engineering Use Case:
Sector / ApplicationEngineering Use Case Details
Fire brigades and Civil Defence stationsA ball valve in the operator's hand to control water without returning to the network valve
Industrial plants and factoriesA 2.5 inch inlet for higher-flow firefighting networks, with the nozzle chosen to suit the pump pressure
Warehouses and distribution centresA 1.5 inch inlet for hose reels and indoor fire hose cabinets
Oil and gas facilitiesAn aluminium body in a natural finish and a light weight for extended handling during operations
Commercial buildings and towersThe light weight matters when holding the branch pipe on stairs and raised platforms
Marine protection and portsA straight jet with long reach for the open distances found on quaysides

B2B Supply Info

FieldValue
Lead Time2-3 Business Days
CoverageRiyadh · Dammam · Jeddah · Jubail · Yanbu · All KSA
Project SupplyAvailable — contact sales team to survey the number of hose cabinets and their coupling type before the supply order is raised

Frequently Asked Questions

Q1: How do I make sure the branch pipe matches our hoses?

  • By checking the coupling type in your hose cabinets first. This branch pipe comes with an NST thread in 1.5 or 2.5 inch, an American thread with a defined form and pitch that does not match British instantaneous couplings or BSP threads. A mismatched branch pipe cannot be fitted and cannot be adapted on site. The product data states that connections are available "as required", so if your network uses a different coupling, contact our sales team before ordering.

Q2: What do the ball valve and shut-off lever give me?

  • They put control of the water in the operator's hand rather than at the distant hose cabinet valve. Water can be stopped instantly to advance, to reposition or to avoid flooding what need not be flooded, then reopened at once. A ball valve specifically gives quarter-turn opening and closing of the lever, with less resistance to flow in the fully open position than other valve types.

Q3: How do I choose the nozzle size?

  • Nozzle size sets the relationship between flow and reach at a given pressure: a smaller nozzle (16 mm) gives greater reach at a lower flow, a larger one (22 mm) gives a higher flow at a shorter reach, and 20 mm is the standard size supplied by default. The choice rests on the pump pressure and flow actually available on your network, and we recommend consulting the network engineer before fixing the size for bulk quantities.

Q4: What is the rated working pressure?

  • The manufacturer's data sheet gives two pressure figures — 7 to 16 bar and 21 bar — without identifying which is the working pressure and which is the test pressure. Because that figure feeds directly into the project specification and into pump selection, we request written confirmation from the manufacturer with every project order before relying on it. Contact our sales team for the confirmation applying to your order.

Q5: Is delivery available to Riyadh, Dammam, and all KSA regions?

  • Yes, supply is available across all KSA regions with bulk quantities available for equipping hose cabinets and firefighting networks, with the inlet size and nozzle size specified per site at order time.

Internal Links

_________________________________________________________________________________________

Copyright © 2026 - (Al-Najma Al-Wataniyah Est.) - All Rights Reserved - KSA

We are committed to providing the highest quality standards for our customers in the Kingdom of Saudi Arabia, supplying accreditation certificates or approved technical data sheets for every product so your project requirements are met.

See more View less