Overview:
- UL-Certified Fire-Rated Single-Leaf Steel Door by alnajmaalwataniyah delivers premium emergency-exit and stairwell protection for major KSA construction projects, engineered from 1mm GI Zero Spangle leaf and 1.5mm fully-welded frame with honeycomb infill — delivering up to 120-minute (2-hour) fire resistance and certified to UL 10(c), UL 10(b), NFPA 252 (2017), and Intertek WH US Mark.
- Available through alnajmaalwataniyah with fast project supply across all KSA regions, fully compliant with Saudi Civil Defense and Vision 2030 requirements.
Technical Specifications:
- Category:Certified Steel Fire Door
- Type:Single-Leaf
- Fire Rating:Up to 120 min
- Door Leaf:1.0 mm GI Zero Spangle Steel
- Door Frame:1.5 mm GI Zero Spangle — Fully Welded
- Door In-Fill:Honeycomb Core
- Structural Opening:990 × 2105 mm
- Overall Frame:980 × 2100 mm
- Leaf Width:894 × 2051 mm
- Door Handing:RH أو LH / RH or LH
- Finish Color:Light Grey (Powder Coated)
- Leaf Construction:0-Conventional Seam
- Assembly Type:Welded Frame + Hinged Leaf
- Country of Origin:Oman
- Certifications:UL 10(c) · UL 10(b) · NFPA 252:2017 · Intertek WH (WHI22-32814226)
Model & Fire Rating:
- Model:FD-SD1-120
- Rating:120 min
- Handing:RH/LH
- Use:Main staircases & Emergency exits
Certificates & Standards:
- Safety Standards: Certified to the most rigorous international fire-door standards:
- UL 10(c) — 2016: Positive Pressure Fire Tests of Door Assemblies
- UL 10(b) — R2015: Fire Tests of Door Assemblies
- NFPA 252:2017: Standard Methods of Fire Tests of Door Assemblies
- Intertek WH US Mark: Certificate WHI22-32814226
- Fully compliant with Saudi Civil Defense — suitable for Vision 2030 mega-projects, SEC/SCECO installations, and Aramco-grade industrial facilities.
- ✓ UL 10(c) ✓ UL 10(b) ✓ NFPA 252 ✓ Intertek WH ✓ Civil Defense ✓ Vision 2030
Industrial Applications:
B2B Sectors:
- Vision 2030 mega-projects (NEOM, Diriyah, Red Sea, Qiddiya, Roshn)
- Hospitals and medical facilities (MoH + private hospitals)
- Schools and universities (MoE + private universities)
- Residential and office towers, hotels
- Shopping malls and retail centers
- Airports and public transit stations
- Industrial plants and refineries (Aramco/SABIC/Maaden)
- Power and water plants (SEC/SWCC)
- Logistics warehouses and distribution centers
- Data centers and critical IT infrastructure
- Government buildings and ministries
Technical & Consulting Sectors:
- Major Construction & Contracting Companies
- Fire Safety Consulting Firms
- Civil Defense Approved Consultants
FAQ:
Q1: What is the difference between UL certification and NFPA certification for fire doors?
- A: UL (Underwriters Laboratories) is an American testing and certification laboratory that tests doors according to its own standards (UL 10b for neutral pressure testing, and UL 10c for positive pressure testing). NFPA sets the standard and requirements for testing (specifically NFPA 252 for fire door assemblies). UL-certified doors are tested in accordance with NFPA requirements, meaning that a UL certification inherently includes NFPA compliance. Our doors carry all three certifications: UL 10(c) + UL 10(b) + NFPA 252.
Q2: What is the appropriate fire rating duration for my project?
- A: It depends on the building type, Saudi Building Code (SBC) requirements, and Civil Defense regulations:
- 20 minutes: For smoke barriers and simple corridors.
- 45 minutes: For light partitions and offices.
- 60 minutes: For residential apartments and unit separations.
- 90 minutes: For main corridors and mechanical rooms.
- 120 minutes (2 Hours): For escape staircases, emergency exits, and critical protection zones (the most requested option for major facilities).
Q3: What is a "Panic Device" and when is it mandatory?
- A: A Panic Exit Device (push bar) allows the door to be opened with a simple push from the inside during emergency evacuations—without needing a handle or a key. It is mandatory for emergency exits, escape staircases, and any area where an occupancy load exceeding 50 people is expected, according to Saudi Civil Defense requirements. Our doors are equipped with the DT-F-1500RA-P Panic Exit Device from Hefei Dortec.
Q4: What is the maximum order quantity and lead time?
- A: There is no maximum limit
Q5: Do the doors include accessories (hinges, door closer, Panic Bar)?
- A: Yes, the doors come as a complete package with an integrated Hefei Dortec ironmongery/hardware set:
- 3x DDSS001FR-4x3x3-SS304 Hinges (Stainless Steel Ball Bearing).
- OUBAO-503BC Door Closer.
- DDDS001 Door Stopper.
- DT-F-1500RA-P Panic Exit Device (Silver Finish).
- DT-H203-P SSS External Lever Trim Handle with Cylinder.
Internal Linking:
- 1. Explore the full UL-Certified Fire Door range (6 variants: UL Certified · Glazed · Security · Bottom Louver · Stainless Steel · Wooden Finish).
- 2. See Armexia's complete Integrated Fire Safety System (extinguishers · foam concentrates · fire blankets · FR tarpaulins · fire doors).
- 3. Contact our B2B Projects Team for shop drawings, material submittal, and bulk quotes.
- 4. Browse compatible Hefei Dortec hardware (hinges · closers · panic exits · levers).
_________________________________________________________________________________________
- We at (Al-Najma Al-Wataniyah Est) are committed to providing the highest standards of quality for projects across the Kingdom of Saudi Arabia and the GCC countries. All our doors come with a complete project documentation package to ensure material approval by consultants and Civil Defense:
- Certifications - Shop drawings - Material Submittal - Fire Test Reports
- Copyright © 2026 — (Al-Najma Al-Wataniyah Est). All Rights Reserved.